Cnfg Led Is Lit; Cpu Led Is Lit - Avaya Aura S8800 Maintaining

Server for sip enablement services
Hide thumbs Also See for Aura S8800:
Table of Contents

Advertisement

CNFG LED is lit

The CNFG LED on the light path diagnostics panel is lit when a hardware configuration error
occurs. This LED is used with the MEM and CPU LEDs.
Troubleshooting steps
Procedure
1. Check that the memory modules are installed in the correct sequence.
2. Check that the memory modules are properly seated.
3. Replace the server.
Related topics:
Sequence for populating DIMM connectors
Sequence for populating DIMM connectors
Removing a memory module
Removing a memory module
Installing a memory module
Installing a memory module

CPU LED is lit

When only the CPU LED is lit, a microprocessor has failed.
When the CPU and CNFG LEDs are lit, an invalid microprocessor configuration has
occurred.
Troubleshooting steps
Procedure
1. Determine whether the CNFG LED is also lit.
Maintaining the Avaya S8800 Server for Avaya Aura
on page 20
on page 20
on page 22
on page 22
• If the CNFG LED is not lit, a microprocessor has failed.
Troubleshooting light path diagnostic LEDs