FUTABA T32MZ Instruction Manual page 113

Digital proportional radio control system
Hide thumbs Also See for T32MZ:
Table of Contents

Advertisement

The telemetry sensor slot number and which sensor is
used in each slot can be changed in this screen.
Since the sensor in each slot is determined at initialization
and the same slot number is memorized even for sensors
sold separately, sensors can be used by simply connecting
them to S.BUS2. When customizing the sensors yourself,
perform the settings in this screen.
*Three slots of altitude sensor are used.
*Eight slots of GPS sensor are used.
< Assignable slot >
The required
Sensor
number of slots
TEMP (SBS-01T, SBS-
01TE)
RPM (SBS-01RM,
SBS-01RO, SBS-
01RB)
Airspeed (SBS-01TAS)
Voltage (SBS-01V)
Altitude (SBS-01/02A)
Current (SBS-01C)
S.BUS2 Servo sensor
(SBS-01S)
GPS (SBS-01/02G)
TEMP125-F1713
VARIO-F1712
VARIO-F1672
CURR-F1678
GPS-F1675
Kontronik ESC
ROXXY
JetCat V10
PowerBox
*Altitude sensors, GPS sensors and other data sensor units may use multiple slots.
*The sensor which uses two or more slots has restriction in a start slot.
The number which can be used as a start slot
1 slot
1 slot
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
6 slots
8 slots
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
8 slots
8 slots
5 slots
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 , 2 4 , 2 5 , 2 6
1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 5 , 1 6 , 1 7 ,
14 slots
16 slots
Servos are classified by CH, but
from
to
.
sensor units may use
By the sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a
When 2 or more of the same kind of sensor
are used, the sensors themselves must allocate
unused slots and memorize that slot.
1 〜 31
1 〜 31
1 〜 31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 ,
2 4 , 2 5 , 2 6
8 , 1 6 , 2 4
1 〜 31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
8 , 1 6 , 2 4
8 , 1 6 , 2 4
1 8
8 , 1 6
are
. There are
and other data
.
.
Selling area
Global
Europe
< Linkage Menu >
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

32mz

Table of Contents