Connection and parameter assignment
The DCOPS signal can be connected to SIDOOR ATD4xxW controllers via "Input 1" of the
terminal X6. See also Section Digital input signals (Page 131).
The connected signal must be activated via the SIDOOR Service Tool (
General setup > Special parameters > Input 1
Note
The type 2 ESPE, pressure-sensitive edge and DCOPS functions cannot be implemented
simultaneously.
SIDOOR ATD410W/ATD420W/ATD430W
The DCOPS signal can be sent as shown in Image 6-26 Sensor signals (Page 159), via the
process image (see Table 6-75 DCMD expansion bits (Page 207)) and/or via the local
sensor input ("Input 1" via p4600 - see Table 6-38 Other parameters (Page 172)).
Note
• The status of the sequential control must be considered when using the DCOPS signal
(process image). The process data is only valid in the "S4: Z_ operation" state (see Image
6-33 Sequential control state graph (Page 216)).
• The light barrier and DCOPS functions can be implemented simultaneously by
connecting to a fieldbus system (process image).
• The DCOPS, type 2 ESPE or pressure-sensitive edge functions cannot be implemented
simultaneously as sensor functions at input 1.
You can find more detailed information on DCOPS in Section Overview (Page 159).
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
).
Controllers
6.2 Drive functions
Main menu >
43