Wiring
Table 6- 30
Pin
1
2
3
4
1)
5
6
7
8
9
Shield
with SIDOOR ATD420W
1)
Connection
The wired PROFIBUS connector is connected to connection X705 and fastened by
tightening the screws.
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Assignment of X705
Assignment
Description
NC
Not connected
NC
Not connected
RS 485P
RS 485 interface (receive and send signals (+))
Note: for 6GK1500-0FC10: "B" (red)
CNTR-P
Repeater direction control
GND
Interface ground
P5V
5 V max. 10 mA, to be used in connector for bus network terminator
only
NC
Not connected
RS 485N
RS 485 interface (receive and send signals (-))
Note: for 6GK1500-0FC10: "A" (green)
NC
Not connected
Shield
FE - functional grounding (bus cable shield)
6.6 Connecting terminals and interfaces