Siemens SIDOOR AT40 System Manual page 176

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
6.7 Parameters
Parameter ID
Adjustment range
p1231
1 ... 100
p1232
1 ... 100
Output transmission
p4602
88...384
ImpulseStop
p1240
1 ... 100
p1241
1 ... 100
176
Factory set-
Unit
ting
60
%
60
%
0
mm/rev
50
%
50
%
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
Description
Threshold value for digital detection of external slide
support during the opening movement
(The proportion of force from which AssistedDrive is
detected in relation to the learnt reference value)
Threshold value for digital detection of external slide
support during the closing movement
(The proportion of force from which AssistedDrive is
detected in relation to the learnt reference value)
Motor M4, MDG400. MDG400 NMS and M5
→ Value configurable. The permitted values are be-
tween
88...384 mm/rev.
M3 motor
→ read value.
Limit value for digital detection of an external oppos-
ing force during the opening movement
(The proportion of force before ImpulseStop is de-
tected in relation to the learnt reference value/friction
force)
Limit value for digital detection of an external oppos-
ing force during the closing movement
(The proportion of force before ImpulseStop is de-
tected in relation to the learnt reference value/friction
force)
System Manual, 06/2016, A2B00096162-AN

Hide quick links: