Connecting and commissioning
6. The display on the controller is as follows:
– The 7-segment display (H401) shows "H.". The decimal point in the 7-segment display
– The LCD display (H1) shows "'H': learn run activated".
7. The door can now be opened with the OPEN button (S402 / S2
– The 7-segment display (H401) shows "o" while the door is opening.
– During the opening, the LCD display (H1) shows "'o': error-free".
8. Switch off the controller by pulling out the power plug or the connector X3 / X1000
Connecting the SIDOOR AT-EB expansion unit (optional, only with SIDOOR ATD400S and
ATE250S)
1. Connect the controller to the SIDOOR AT-EB expansion unit via the serial interface
(connector X8).
Only use a recommended connecting cable. See Section Accessories (Page 23).
284
(H401) flashes during the save process.
The 7-segment display (H401) shows "u" when saving has finished. If a light
barrier/pressure-sensitive edge
because X6 is not yet connected. For the M4, MDG400. MDG400NMS and M5
motors, the determined door weight is shown on the LCD for the initial commissioning
or motor adaptation.*
* SIDOOR ATD4xxW
The LCD display (H1) finally shows "'u': door is closed".
is used, the 7-segment display (H401) shows "0."
2)
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
1)
)
1)
1)
.