Parameter
Hold-open time after motion
detector
Hold-open time after obstruc-
tion
Delay time in wait mode CLS s
Delay time in wait mode
OPEN
Number of blockages before
wait mode CLS
Number of blockages before
wait mode OPEN
Limited time motion detector
Time delay before movement ms
Reversal distance CLS
Table A- 18
SIDOOR M4 L / R adjustment ranges
Parameter
Creep distance OPEN
Cutter distance OPEN
Creep distance CLOSE
Cutter distance CLOSE
Maximum speed OPEN
Creep speed OPEN
Cutter speed OPEN
Initial speed OPEN
Maximum speed CLOSE
Creep speed CLOSE
Cutter speed CLOSE
Initial speed CLOSE
NDG speed (reduced)
Acceleration ramp OPEN
Braking ramp OPEN
Reversing ramp OPEN/CLOSE
Acceleration ramp CLOSE
Braking ramp CLOSE
Reversing ramp CLOSE/OPEN
Continuous torque (power) OPEN
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Unit
AT40
ATD400V
s
--
--
s
--
--
--
--
s
--
--
cnts
--
--
cnts
--
--
min
--
--
--
--
mm
--
--
Parameter ID
p3660
p3661
p3662
p3663
p3664
p3665
p3666
p3667
p3668
p3669
p3670
p3671
p3672
p3673
p3674
p3675
p3676
p3677
p3678
p3679
A.1 Profiles and adjustment ranges
Adjustment range
ATD400K
ATD400W
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Unit
Adjustment range
ATD4xxW
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm/s
100 ... 800
30 ... 800 (V1.03 and higher)
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
100 ... 800
30 ... 800 (V1.03 and higher)
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
50 ... 800
30 ... 800 (V1.03 and higher)
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
A
0 ... 2,5
Appendix
ATD400S
ATD400T
--
0 ... 60
--
0 ... 20
--
0 ... 600
--
0 ... 600
--
0 ... 20
--
0 ... 20
--
0 ... 60
--
0 ... 5000
--
6 ... 50