Siemens SIDOOR AT40 System Manual page 182

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
6.7 Parameters
FBLOCK-REF parameters
The inputs of the various F blocks can be connected or linked to any "Q" outputs (signal
sources) via the following FBLOCK-REF parameters. To this end, the number of the Q
element must be entered directly in the REF parameter (Q{0 to 38}).
Table 6- 45
FBLOCK-REF parameters
Parameter ID
Name
AND
p20100
REF_AND0_IN1
p20101
REF_AND0_IN2
p20102
REF_AND0_IN3
p20103
REF_AND0_IN4
p20104
REF_AND1_IN1
p20105
REF_AND1_IN2
OR
p20106
REF_OR0_IN1
p20107
REF_OR0_IN2
p20108
REF_OR0_IN3
p20109
REF_OR1_IN1
p20110
REF_OR1_IN2
p20111
REF_OR1_IN3
NOT
p20112
REF_NOT0_IN1
p20113
REF_NOT1_IN1
XOR
p20114
REF_XOR0_IN1
p20115
REF_XOR0_IN2
FRQ
p20116
REF_FRQ0_IN1
p20117
REF_FRQ1_IN1
DELAY
p20118
REF_OnDELAY_IN1
Special
p20119
REF_ACK
p20120
REF_BATTMODE
COUNTER
p20121
REF_COUNTER_IN
p20122
REF_COUNTER_RESET Reset input of the counter (counter is reset to 0)
182
Description
Input 1 logical AND gate 0
Input 2 logical AND gate 0
Input 3 logical AND gate 0
Input 4 logical AND gate 0
Input 1 logical AND gate 1
Input 2 logical AND gate 1
Input 1 logical OR gate 0
Input 2 logical OR gate 0
Input 3 logical OR gate 0
Input 1 logical OR gate 1
Input 2 logical OR gate 1
Input 3 logical OR gate 1
Input logical NOT gate 1 (negation)
Input logical NOT gate 2 (negation)
Input 1 logical exclusive OR (XOR)
Input 2 logical exclusive OR (XOR)
Input frequency detection
Input frequency detection
ON delay
Fault acknowledgement (preceded by 5 s ON delay)
Emergency power operation (drive order is latched automatically until the next
end stop is reached)
Count input of the counter (a positive edge increments the counter)
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN