Siemens SIDOOR AT40 System Manual page 158

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
6.6 Connecting terminals and interfaces
Fieldbus communication modules (USS, PROFIBUS, PROFINET)
Table 6- 32
Relay control, fieldbus modules
Terminal
Assignment
X100.1
CLOSE
X100.2
(closed)
X100.3
OPEN
X100.4
(open)
Connection
The wired relay connector is connected to connection X100.
158
Description
The relay is additionally influenced by the sensor configuration (parameter p4600).
See also Section Sensors and external sensor interface module (ATD4xxW)
(Page 159).
Sensor function test inactive
The system's internal door state "closed" is signaled via this relay (relay con-
tact is closed). This state is not only position-dependent. Note the following
conditions:
The "closed" state can only be achieved with a drive order.
The "closed" state cannot be achieved by external pushing.
The "closed" state can be terminated by means of a drive order or external
pushing.
Sensor function test active
The "TestOUT" sensor function test signal is output.
The system's internal door state "open" is signaled via this relay (relay contact is
closed).
This state essentially depends on the current door position.
The "open" state can be achieved both by means of a drive order and also by
external pushing.
The "open" state can be terminated by means of a drive order or external
pushing.
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN