Controllers
6.6 Connecting terminals and interfaces
Connection
Risk of injury due to electrical voltages
The protective cover has to be removed to connect the CAN cable or to activate/deactivate
the terminating resistor.
Perform the following protective measures before removing the protective cover:
• Disconnect the controller from all live cables.
• By grounding, ensure that the user/fitter, the controller and other conductors have the
Table 6- 24
Pin assignment
Table 6- 25
Pin assignment
The bus can be terminated with 120 ohms via the switch S1.
You will find information about manufacturer-specific CANopen objects at Industry Online
Support on the Internet
(http://support.automation.siemens.com/WW/view/en/50247080/133300).
142
DANGER
same voltage potential.
Observe the general ESD guidelines.
Connector X15
Pin
1
2
3
4
5
6
7
8
Connector X16
Pin
1
2
3
Signal
CAN_H
CAN_L
GND
–
–
Shield
GND
–
Signal
Description
CAN_H
CAN high bus cable
Shield
CAN cable shield
CAN_L
CAN low bus cable
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN