Siemens ATC5300 Software Manual
Siemens ATC5300 Software Manual

Siemens ATC5300 Software Manual

Automatic transfer controller, remote control
Hide thumbs Also See for ATC5300:

Advertisement

Quick Links

s
ATC5300
Automatic Transfer Controller
Remote Control Software Manual
Edition 03/2011
A5E02469028-02
General Information
Connection
User Interface
Menus
1
2
3
4

Advertisement

Table of Contents
loading

Summary of Contents for Siemens ATC5300

  • Page 1 General Information Connection User Interface ATC5300 Menus Automatic Transfer Controller Remote Control Software Manual Edition 03/2011 A5E02469028-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Keyboard Lock-Unlock ............19 ATC5300...
  • Page 4 Table of Contents ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 5: General Information

    Graphic card with 1024x768 or higher resolution • A free standard RS 232 serial interface (COM:) • 64 Mb of RAM • Pentium® class or higher processor • CD-ROM drive for installation ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 6: Installation

    6. Follow the instructions that will be shown until the end of installation. 7. Reboot the PC. Technical Support For further assistance, refer to: Technical Support on the Internet: Internet address of Technical Support http://www.siemens.com/lowvoltage/technical-support ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 7: Connection

    Function setup and set one different RS 485 serial address for each ATC, starting from address 01. Make sure that the PC speed and parity settings match the ATC RS 485 setting. ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 8 A 6.3 A 6.3 250V 5A 250V 5A TR 6.4 TR 6.4 LINE 2 LINE 2 VOLTAGE INPUTS VOLTAGE INPUTS RS 485 RS 485 TWISTED-PAIR CABLE TWISTED-PAIR CABLE L MAX = 1200m ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 9: User Interface

    Model and release of the internal firmware of the ATC connected • Serial communication status (ONLINE = connection active, OFFLINE = connection not active) • ATC operating mode • Any alarm conditions • Page refresh rate ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 10 Displays Inputs - Outputs status Ç Frequency reading Switches locking of the ATC keypad ON/OFF È Voltage readings Drop-down box to select the controller in RS 485 multi-drop É networks Icon (Utility / genset) Ê ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 11: System Configuration

    To access the configuration window it is necessary to enter the password. After the first installation, by default, the password is "SIEMENS" (the user can change it later). 1. Click on Password menu, type "SIEMENS" and then confirm with OK.
  • Page 12: Configuration-Options-Controllers

    Description of the ATC. It is used to identify the controller in the main page, data log, events and more. Enables / disables the serial communication with the selected ATC Selected ATC ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 13: Password

    Reset MAX values, event log, operation counters etc. 3.3.1 Password After the first installation the password is "SIEMENS". Later, the user will be able to customize its password, using the New Password button and then entering the new desired password two times.
  • Page 14: Access To Setup Menus

    Load a file from disk and transmit it to the device (Parameters-Load file) • Download the device settings and save them into a file (Parameters-Save file) • Print the device settings (Parameters-Print) ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 15: Offline Programming

    The online file transfer to an ATC can be done only if the file to be uploaded was created for the same ATC model and has a compatible software revision, otherwise the software will give an alarm indication. ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 16 User Interface 3.8 Parameters Files ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 17: Menus

    Code of the parameters Resets the values to the factory-set default Menu title Receives the values of the parameters from the ATC and displays these in the window. Enabled only in online mode. ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 18: View Menu

    The quality of the graphic representation of the front panel may vary according to the graphic resolution of your PC and/or the monitor settings used. Possibility of clicking on the keys Real-time display of the status of the readouts and LEDs Name of the currently selected unit. ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 19: Event Log

    à Event time stamp Export to ASCII file. À Ä Code and description of the event Clear events history. Available only after entering the password. Á Å Close Event log window  ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 20: Statistical Data

    ATC operation history. These data are stored in a non-volatile memory so they are not lost when the ATC is powered down. Two password-protected buttons allow to reset timers and counters. Reset buttons ¿ Time meters À Operation counters Á ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...
  • Page 21: Inputs-Outputs

    Using this function it is possible to lock or unlock the front panel keyboard of the device, preventing unauthorized access to setup settings, memory clearing etc. For further information see the ATC5300 operation manual. ATC5300 Remote Control Software Manual, Edition 03/2011, A5E02469028-02...