Siemens SIDOOR AT40 System Manual page 201

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Parameter page index
The page index is used to select parameter pages. This enables the PNU value range to the
extended (0 to 1999). The resulting parameter ID then has the value range from 0 to 65,999.
The page index is coded in bits 10 to 15 of the high byte of IND.
Bits 8 and 9 are reserved, and not used.
The page index is defined as multiple of 2000. The binary representation is also scrambled.
The exact assignment of the bits is described below.
Table 6- 64
Parameter page index
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10
a
d
c
Table 6- 65
Page index assignment
Value range of parameter ID
from
to
0000
1999
2000
3999
4000
5999
6000
7999
8000
9999
...
...
32.000
33.999
...
...
64.000
65.999
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Bit 9
b
f
e
Bits for page index
a
d
c
0
0
0
1
0
0
0
0
0
1
0
0
0
0
1
...
...
...
0
0
0
...
...
...
0
0
0
6.11 Structure of user data/process data
IND
Bit 8
Bit 7
Bit 6
Bit 5
b
f
e
0
0
0
0
0
0
1
0
0
1
0
0
0
0
0
...
...
...
0
0
1
...
...
...
0
1
0
Bit 4
Bit 3
Bit 2
Hex
+ parameter number (PNU)
value
0x00
0x0000 to 0x07CF
0x80
0x0000 to 0x07CF
0x10
0x0000 to 0x07CF
0x90
0x0000 to 0x07CF
0x20
0x0000 to 0x07CF
...
0x04
0x0000 to 0x07CF
...
0x08
0x0000 to 0x07CF
Controllers
Bit 1
Bit 0
201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents