Siemens SIDOOR AT40 System Manual page 230

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
6.16 Technical specifications
Standard for EMC
Certificate of suitability
CE marking
Standard for safety
Note
SIDOOR ATD400T relay (6FB1121-0BM13-3AT2) – supplementary technical specifications
• Maximum output current at 24 V DC:
– 0.4 A at ≤ 55 °C ambient temperature during operation
– 0.1 A from 55 °C to 70 °C ambient temperature during operation, with restrictions at
• Maximum ambient temperature during operation:
– 55 °C
– 70 °C with restrictions at operating temperatures > 55 °C
• Restrictions at operating temperatures > 55 °C:
– Use the 24 V output voltage only for operating the control inputs (max. 0.1 A)
– Use a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate
– The maximum drive parameters are restricted to the default values
– If temperature class T3 according to EN 50155 is used, the maximum air temperature
230
6FB1231-0BM10-0AT3
EN 12015:2004 / EN
12016:2009 / EN
61000-6-4:2011 / EN
61000-6-2:2006 / EN
50121-3-2:2006 /
50121- 5:2007
Yes
EN 60950-1:2011
operating temperatures > 55 °C
of 85 °C must not be exceeded near the printed-circuit board
6FB1131-0BM10-3AT3
EN 61000-6-2 / EN
61000-6-4
Yes
ISO 13849-1 PLd
CAT2
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
6FB1121-0BM13-3AT2
EN 50121-3-2
Yes