Parameter ID
Adjustment range
p3874
0 ... 60000
1)
p3875
0 ... 60000
1)
p3876
0 ... 60000
1)
Retries
p3877
0 to 0xFFFF
0 ≙ no retry
0xFFFF ≙ unlimited
retries
p3878
0 ... 60000
p3879
0 ≙ deenergize
1 ≙ stop
p3880
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
Reversing
p3881
0 to 0xFFFF
0 ≙ no reversing
0xFFFF ≙ unlimited
reversing
p3882
0 ... 60000
p3883
0 ... 60000
0 ≙ full reverse
p3884
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
p3885
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
Expert parameters, see Section Expert configuration (Page 64).
1)
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Factory setting Unit
10
mm
20
mm
50
mm
3
0 (V1.03 and
higher)
2000
ms
0
0
0
1 (V1.03 and
higher)
2000
ms
0
mm
200 (V1.03
and higher)
0
0
Description
Range of suppression of obstruction detection
before the open end stop
Range of suppression of force obstruction detec-
tion before the creep distance
Range of suppression of force obstruction detec-
tion after the last obstruction
Number of retries to overcome the obstruction
Wait time before each retry
Drive control during the wait time (before retries)
Drive control after all retries have been executed
(if reversing is not configured)
Number of reverses
Wait time before each reverse
Reversing distance
Drive control for obstruction while reversing
Drive control after all reverses have been execut-
ed
Controllers
6.7 Parameters