Siemens SIDOOR AT40 System Manual page 226

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Controllers
6.16 Technical specifications
Standard for EMC
Certificate of suitability CE
marking
Standard for safety
Requirement class for protec-
tive devices acc. to EN
12453, section 5.5.1
Order number
General technical data:
product brand name
Product designation
Design of the product
Manufacturer's article number
/ usable
of the motor
of power supply unit
Overvoltage category
Supply voltage:
Supply voltage / at DC
Supply voltage / at DC /
rated value
Consumed active power
rated value
maximum
in standby mode /
rated value
Inputs/ Outputs:
Input voltage / per DC input
minimum
maximum
Input current / per DC
input
Product feature
Isolated control inputs
Control inputs switch-
ing to P potential
Output voltage / at DC
226
6FB1141-1AT10-3KU2
EN 61000-6-2 / EN 61000-6-
3
Yes
ISO 13849-1 PLd CAT2
Protection level C
6FB1141-1AT11-
3WE2
SIDOOR
Door controller
ATD401W
6FB1103-0AT11-3MC0, 6FB1103-0AT10-4MB0, 6FB1103-0AT10-3MC0,
6FB1103-0AT11-3MC0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-4MB0,
6FB1103-0AT14-4MB0, 6FB1103-0AT14-3MC0, 6FB1103-0AT13-3MC0,
6FB1103-0AT11-3MD0, 6FB1103-0AT10-3MD0
6FB1112-0AT20-2TR0, 6FB1112-0AT20-3PS0
2
V
19.2 ... 38
V
36
W
145
W
540
W
5
V
10
V
28
mA
9 ... 27
Yes
Yes
V
24
6FB1141-4AT10-
6FB1141-2AT10-
3WE2
3WE2
ATD410W
ATD420W
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
6FB1141-1AT11-3KU2
EN 61000-6-2 / EN 61000-6-
3
Yes
ISO 13849-1 PLd CAT2
Protection level C
6FB1141-3AT10-
3WE2
ATD430W

Hide quick links: