9.2 DRIVE-CLiQ coupling

9.2
DRIVE-CLiQ coupling
9.2.1

Description

The DRIVE-CLiQ coupling is used to connect 2 DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to IEC 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
You can find information on the permissible cable length in Chapter DRIVE-CLiQ signal
cables (Page 361)
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
• Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
9.2.2

Interface description

9.2.2.1

Overview

Figure 9-10
342
respective application.
Rating plate
Protective cap, Yamaichi, Article No.: Y-ConAS-24-S
Interface overview, DRIVE-CLiQ coupling