Siemens SINAMICS S120 Manual page 365

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

DRIVE-CLiQ signal cable
Rated voltage V
/V in
0
accordance with EN 50395
Test voltage, rms
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. travel velocity
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
The UR/CSA file number is stamped on the cable sheath.
1)
Acceleration characteristics, refer below
2)
Characteristics for MOTION-CONNECT 800PLUS
The cables can be used in the area below the characteristic. The characteristics represent
the tested operating points.
Acceleration levels for signal and power cables (up to
16 mm²)
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
DRIVE-CLiQ
30 V
500 V
-20 ... +80 °C
-
45 N/mm
2
_
50 mm
-
-
-
-
-
CFC/silicon-free
EN 60811-2-1
PVC
Gray RAL 7032
EN 60332-1-1 to 1-3
Cabinet design and EMC for components, Blocksize format
DRIVE-CLiQ
MOTION-CONNECT 500
30 V
500 V
-20 ... +80 °C
0 ... 60 °C
80 N/mm
2
30 N/mm
2
35 mm
125 mm
30 °/m absolute
100000
30 m/min
2 m/s
2
CFC/silicon-free
EN 60811-2-1
(mineral oil only)
PVC
DESINA color green
RAL 6018
EN 60332-1-1 to 1-3
Acceleration levels for power cables (25 mm², 35 mm² and
50 mm²)
10.6 Connection Methods
DRIVE-CLiQ
MOTION-CONNECT 800PLUS
30 V
500 V
-20 ... +80 °C
-20 ... +60 °C
50 N/mm
2
20 N/mm
2
35 mm
75 mm
30 °/m absolute
10 million
300 m/min
50 m/s
(3 m distance moved
2
through)
2)
CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color green, RAL 6018
EN 60332-1-1 to 1-3
365