NOTICE
Damage to the du/dt filter compact by exceeding the maximum pulse frequency
The maximum permissible pulse frequency when using a du/dt filter compact is 4 kHz. The
du/dt filter compact can be damaged if the pulse frequency is exceeded.
• When using the du/dt filter compact, operate the Motor Module with a maximum pulse
NOTICE
Damage to the du/dt filter compact if it is not activated during commissioning
The du/dt filter compact may be damaged if it is not activated during commissioning.
• Activate the du/dt filter compact during commissioning using parameter p0230 = 2.
NOTICE
Damage to the du/dt filter compact if a motor is not connected
du/dt filters compact which are operated without a motor being connected can be damaged
or destroyed.
• Never operate a du/dt filter compact connected to the Motor Module without a
Note
Cable lengths
Keep the connecting cables to the Motor Module as short as possible (max. 5 m). Use an
equivalent cable type when replacing the cables supplied.
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
frequency of 4 kHz.
connected motor.
Motor-side power components
6.2 Chassis
211