Accessories

9.1

DRIVE-CLiQ cabinet bushings

9.1.1

Description

A DRIVE-CLiQ cabinet bushing is used to connect the DRIVE-CLiQ cables between the
inside and outside of the control cabinet. It is used in a control cabinet panel. The data lines
and the voltage supply contacts of the DRIVE-CLiQ are also routed through the bushing. The
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ cables is available with DRIVE-CLiQ
connector and M12 connector/socket.
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ connectors
The cabinet bushing has degree of protection IP54 according to IEC 60529 from the outside
towards the inside. Inside the control cabinet, a connection is established according to
degree of protection IP20 or IPXXB acc. to IEC 60529. So that the complete outside of the
cabinet bushing, including the DRIVE-CLiQ interface, has degree of protection IP54, a
DRIVE-CLiQ cable must be used, which as a minimum must also have degree of protection
IP54.
DRIVE-CLiQ cabinet bushing for M12 connector/socket
The cabinet bushing has degree of protection IP67 according to IEC 60529 from the outside
towards the inside. Inside the cabinet a connection according to degree of protection IP67 in
compliance with IEC 60529 is realized.
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
• Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
respective application.