Safety Data For Power Modules, Chassis Format - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

System overview
2.5 System data
2.5.2

Safety data for Power Modules, chassis format

Table 2- 5
Electrical data
Line connection voltage
Rated pulse frequency
Line system types
Line frequency
Radio interference suppression
Output voltage
Electronics power supply
implemented as PELV circuit according to
EN 61800-5
Short-circuit current rating SCCR according
to UL508C (up to 600 V)
Overvoltage category
Degree of pollution
100 % output voltage only possible with modulation type "edge modulation" (FLM).
1)
When using a motor holding brake, possibly restricted voltage tolerances (24 V ±10 %) must be taken into account.
2)
Table 2- 6
Degree of protection / protection class
Degree of protection
Protection class, line supply circuits
Electronic circuits
Table 2- 7
Environmental conditions
Chemically active substances
Long-term storage
Transport
Operation
Biological environmental conditions
Long-term storage
Transport
Operation
Climatic environmental conditions
Long-term storage
Transport
38
3 AC 380 ... 480 V ±10 % (in operation -15 % < 1 min)
2 kHz
Grounded TN/TT line systems and non-grounded IT line systems
47 ... 63 Hz
According to EN 61800-3
Approx. 0.95 • line voltage (maximum value)
24 V DC -15 / +20 %
electronics
1.1 ... 447 kW: 65 kA
UL certification applies only in conjunction with the fuses prescribed by
Siemens and not with other types or circuit breakers alone.
III to EN 61800-5-1
2 according to EN 61800-5-1
IPXXB according to EN 60529, open type according to UL 508
I (with protective conductor connection) according to EN 61800-5-1
protective extra low-voltage (PELV/SELV)
Class 1C2 according to EN 60721-3-1, in product packaging
Class 2C2 according to EN 60721-3-2, in transport packaging
Class 3C2 according to EN 60721-3-3 (for the drive system)
Class 3C3 according to EN 60721-3-3 (for the Power Modules)
Class 1B1 according to EN 60721-3-1, in product packaging
Class 2B1 according to EN 60721-3-2, in transport packaging
Class 3B1 according to EN 60721-3-3
Class 1K4 according to EN 60721-3-1, in product packaging
Temperature: -25 ... +55 °C
Class 2K4 according to EN 0721-3-2, in product packaging
Temperature: -40 ... +70 °C
max. Air humidity: 95% at +40°C
1)
, ground = negative polarity grounded through the
2)
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
1)
2)
1)
2)
1)
2)
AC Drive

Advertisement

Table of Contents
loading