Comparison Of Motion-Connect Power Cables - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet design and EMC for components, Blocksize format
10.6 Connection Methods
10.6.2.2

Comparison of MOTION-CONNECT power cables

MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. MOTION-
CONNECT 800PLUS power cables fulfill all of the high mechanical requirements for use in
tow chains. They are resistant to cutting oils.
Table 10- 12 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables
Power cable
Approvals
VDE
1)
cURus or UR/CSA
UR-CSA File No.
2)
in conformance with RoHS
Rated voltage V
/V in accordance with EN 50395
0
Supply cores
Signal cores
Test voltage, rms
Supply cores
Signal cores
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. traversing speed
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
The registration number is printed on the cable jacket.
1)
The file number is printed on the cable jacket.
2)
Characteristic for acceleration, see Chapter "Comparison of DRIVE-CLiQ cables".
3)
368
MOTION-CONNECT 500
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
600 V/1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-20 ... 80 °C
0 ... 60 °C
50 N/mm
2
20 N/mm
2
5 x D
max
approx. 18 x D
max
(Details see SIEMENS Industry Mall
(https://mall.industry.siemens.com/mall/
de/ww/catalog/products/7519999?activ
eTab=order&regionUrl=/))
30°/m absolute
100000
30 m/min
2 m/s
2
CFC/silicone-free
EN 60811-2-1 (mineral oil only)
PVC
DESINA color, orange RAL 2003
EN 60332-1-1 to 1-3
MOTION-CONNECT 800PLUS
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
600 V/1000 V
24 V (EN) 1000 V (UL/CSA)
4 kV
2 kV
-50 ... 80 °C
-20 ... 60 °C
50 N/mm
2
20 N/mm
2
4 x D
max
approx. 8 x D
max
(Details see SIEMENS Industry Mall
(https://mall.industry.siemens.com/mall/
de/ww/catalog/products/7519999?activ
eTab=order&regionUrl=/))
30°/m absolute
10 million
From 10 mm
: 3 million
2
Up to 300 m/min
50 m/s
(3 m)
2
3)
CFC/halogen/silicone-free
IEC 60754-1
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color, orange, RAL 2003
EN 60332-1-1 to 1-3
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
AC Drive

Advertisement

Table of Contents
loading

Table of Contents