Drive-Cliq Coupling; Description; Interface Description; Overview - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

Accessories

9.2 DRIVE-CLiQ coupling

9.2
DRIVE-CLiQ coupling
9.2.1

Description

The DRIVE-CLiQ coupling is used to connect 2 DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
You can find information on the permissible cable length in Chapter DRIVE-CLiQ signal
cables (Page 427)
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when DRIVE-CLiQ cables are
used that are either incorrect or have not been approved for this purpose.
• Only use suitable DRIVE-CLiQ cables that have been approved by Siemens for the
9.2.2

Interface description

9.2.2.1

Overview

Figure 9-10
398
particular application.
Rating plate
Protective cap, Yamaichi, order number: Y-ConAS-24-S
Interface overview, DRIVE-CLiQ coupling
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
AC Drive

Advertisement

Table of Contents
loading

Table of Contents