8.2

DRIVE-CLiQ coupling

8.2.1

Description

The DRIVE-CLiQ coupling is used to connect two DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
8.2.2

Safety information

Note
Only Siemens cables should be used for DRIVE-CLiQ connections.
8.2.3

Interface description

8.2.3.1

Overview

Figure 8-5
AC Drive
Manual, (GH6), 07/2007 Edition, 6SL3097-2AL00-0BP2
DRIVE-CLiQ coupling
1
DRIVE-CLiQ coupling
2
Rating plate
3
Centering caps, Yamaichi, order no.: Y-ConAS-24-S
Accessories
8.2 DRIVE-CLiQ coupling