3.3

Setting and Installation

3.3.1 Single Air Flow Sensor Unit Operation

(1)
Outputting Analog Signals
This section describes the Analog Output/Analog Output/Unit Error Output connection.
(1) Connect the connector of the breakout cable (D6FZ-JDA) to the cable connector
socket of the Air Flow Sensor.
Breakout Cable
D6FZ-JDA
Cable Connector Socket
Air Flow Sensor
(2)Connect the following breakout cable wires to the upstream unit as required.
<D6FZ-FGS1000>
Analog Output 1: Black (Pin No. 3)
Analog Output 2: Yellow (Pin No. 4)
Pulse Output: White (Pin No. 1)
Unit Error Output: Red (Pin No. 8)
<D6FZ-FGT>
Analog Output 1: Black (Pin No. 3)
Pulse/Judgment/Unit Error Output: White (Pin No. 1)
Pulse/Judgment/Unit Error Output: Red (Pin No. 8)
Note
Refer to "2.1.3 Input/Output Specifications" for the Analog Output, Pulse Output and
Unit Error Output specifications.
Breakout Cable
D6FZ-JDA
D6FZ-FGT
3-2