■Switching Air Flow Sensor IDs
The following shows the procedure to switch the ID.
・A long press of the ▽ key in each measured value display switches the Air Flow Sensor
IDs in the ascending sequence.
・During a long press of the key, the ID display is switched from one to another at the
interval of 1 second.
・The integrated standard flow rate appears first whenever the ID is switched to another.
01.F01
Integrated Standard Flow Rate
Air Flow Sensor ID is "01".
02.F01
Integrated Standard Flow Rate
"02" is displayed for ID.
08.F01
Integrated Standard Flow Rate
The last ID of the connected Air Flow Sensor units is displayed.
AL.F01
Integrated Standard Flow Rate
The integrated standard flow rate is displayed, if a value other than the integrated
standard flow rate is displayed.
If it is the integrated standard flow rate, then the total flow rate is displayed. (The first
ID will be displayed by forwarding the display)
Note
・The "REC" indication turns ON during data recording.
・"ALM" turns ON when the measured value exceeds the upper and lower threshold range
or the alarm output is ON. To cancel the retained alarm, hold the MODE key.