2.2.3 Input/Output Specifications

(1)
Breakout Cable Wires Color Code (D6FZ-JDA)
The following shows the specifications of the breakout cable connected to the cable
connector socket of an Air Flow Sensor unit.
(2)
Linear Output
Output : Current output (4 to 20 mA)
Load resistance: 300 max.
Output content: Momentary flow
Analog output
4mA
20mA
(3)
ON/OFF Output
Output method
Output stage circuit
diagram
Load power supply voltage
Load current
Output mode
(*)OUT1/OUT2 can be set for any output mode in FUN mode settings.
D6FZ-FGT200
0L/min
200L/min
NPN Open collector output
Inside D6FZ-FGT
26.4VDC max.
50mA max. (Residual voltage 2V max.)
Pulse output (Pulse width : Approx. 50ms)
Judgment output
Unit error output
2-6
2. Part Name and Function
D6FZ-FGT500
0L/min
500L/min

Advertisement

Table of Contents
loading

This manual is also suitable for:

D6fz-seriesD6fz-fgt seriesD6fz-fgx21D6fz-fgs1000