Setting Head Installation; Setting The Emitted Light Amount - Omron ZS-HL User Manual

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

Section5
Setting for Sensing Conditions

Setting Head Installation

Set how the Sensor Head is installed.
This setting is automatically specified according to the type of the connected Sensor
Head. However, if the Head is installed at an angle and the default value and reflection
angle are changed, change the settings according to the status of the head installation.
FUN Mode-[SENSING]-[SETTING]
Setting
DIFFUSE
REGULAR

Setting the Emitted Light Amount

Set the amount of light emitted from the Sensor Head to match the state of the workpiece
surface.
The response may slow down if workpieces having differing reflection factors such as black-and-white
workpieces are measured with FUN mode set to [AUTO]. In this case, narrow the adjustment range by
setting [RANGE]. If this does not increase the response speed to keep up with measurement, select
[FIXED].
FUN Mode-[SENSING]-[LASER]
AUTO
RANGE
FIXED
ZS-HL
5-8
User's Manual
Select this item when the Sensor Head is installed for diffuse reflection sensing.
Select this item when the Sensor Head is installed for regular reflection sensing.
Setting
Automatically adjusts the emitted light amount according to the reflection
factor of the workpiece. Note that the response time varies with each mea-
surement. (default value)
UPPER
Sets the adjustment range for the AUTO setting.
LOWER
If the response speed cannot keep up with measurement at the default
value, narrow the range.
Range: 0.1 to 80 % (default: LOWER 0.1 %, UPPER 80 %)
Level
0.1 %
80 %
Sets the emitted light amount to a fixed value.
For reference levels, see [RANGE].
Range: 0.1 % to 80 %.
Description
Description
Sensitivity
Color of workpiece
Low
Bright
High
Dark

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents