(3) Connect an Air Flow Sensor unit to a T-branch connectors with the double-sided
connector cable (D6FZ-JDB).
(4) In the same way, connect other Air Flow Sensor units using double-sided connector
cables and T-branch connectors.
(3)
Using Alarm Function
Use the provided alarm output connector to connect the OUT and GND alarm output
terminals to the load according to the output specifications. (Refer to "2.3.3 Input/Output
Specifications")
(4)
Connecting to Power Supply
Connect the power supply to the T-branch connector to supply power to the Air Flow Sensor
and Air Flow Station units.
Double-Sided
Connector Cable
D6FZ-JDB
Connection Cable
(Length: 1.5 m)
Air Flow Station
D6FZ-FGX21
(1) Connect the breakout cable (D6FZ-JDA) to the power supply.
Connect the blue wire (Pin No. 7) to 0V and the brown wire (Pin No. 2) of the breakout
cable to DC24V terminals.
Note
Refer to the manual of the power supply to connect for the connection procedure.
(2) Connect the breakout cable connector to the T-branch connector.
T-Branch
Connector
D6FZ-FC02
T-Branch
Connector
D6FZ-FC02
Double-Sided
Connector Cable
D6FZ-JDB
Air Flow Sensor
Air Flow Sensor
D6FZ-FGT
D6FZ-FGT
Max. 8 Air Flow Units can be Connected
3-7
3. Check and Preparation
T-Branch
Connector
D6FZ-FC02
Double-Sided
Double-Sided
Connector Cable
Connector Cable
D6FZ-JDB
D6FZ-JDB
Breakout Cable
D6FZ-JDA
Power Source
(DC24V)
Air Flow Sensor
D6FZ-FGS1000