(4)
Setting for Air Flow Sensor (NN.SET)
Specifies whether the items including Air Flow Sensor pulse setting, Flow rate full-scale
value, Frequency of averaging, and Measurement target gas are displayed or not. The
setting is made for the Air Flow Sensor unit whose ID is selected in RUN mode.
NN : Unit No. of the Air Flow Sensor which is designated by in RUN mode.
The range of selection (Options):
OFF / DISP
Initial value:
OFF
Setting Value
OFF
DISP
Note
The NN.SET setting returns to "OFF" when the unit is reset.
(5)
Pulse Setting
Specifies the integrated flow rate for a single pulse output from the Air Flow Sensor unit. The
pulse toggles ON/OFF when the sensor detects the half of a specified flow rate.
D6FZ-FGS1000
The range of selection (Options):
1.0/10.0/100.0/1000.0 (L/Pulse)
Initial value:
10.0
D6FZ-FGT
The range of selection (Options):
10.0/100.0/1000.0 (L/Pulse)
Initial value:
10.0 (D6FZ-FGT200/500)
Note
The Pulse setting is not available when NN.SET is set to OFF.
The momentary flow units of the Air Flow Station are m
3
m
/Pulse.
(E.g. 1.0 L/Pulse → 0.001 m
(6)
Flow Rate Full-Scale Value
Specifies the flow rate full-scale value for Analog Output 1 from the Air Flow Sensor unit.
The unit does not display the items including Pulse setting, Flow
rate full-scale value, Frequency of averaging, and Measurement
target gas.
The ETC item returns when the ▽ key is pressed after the setting is
applied with the SET/REC/STOP key.
The unit displays the items including Pulse setting, Flow rate
full-scale value, Frequency of averaging, and Measurement target
gas.
The NN.SET item is displayed when the ▽ key is pressed after the
setting is applied with the SET/REC/STOP key.
3
/Pulse , 1000.0 L/Pulse → 1.0 m
4-7
4. Setting (Air Flow Station Operation)
Operation
3
3
/min or m
/h, the unit of pulse is
3
/Pulse )

Advertisement