Honeywell Galaxy Flex Installer Manual page 86

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Parameters [51]
Lockout [51.62.1]
Use this option to set the number of invalid code attempts that can be made before keypad
lockout occurs. Keypad lockout prevents any entry via all keypads associated with the
groups assigned to the keypad where the invalid attempts were made. The lockout lasts for
5 minutes. If you are locked out, and after the lockout period, you can make another x
invalid code attempts before being locked out again, where x is the lockout value.
Entry of a valid code resets the lockout counter. The number of lockout attempts between
each lockout can be programmed between 0 and 10. The default is 5 and 0 disables the
function.
Lockout Tamper [51.62.2]
Use this option to set the number of invalid code attempts that can be made before system
tamper occurs.
The default is 15 and the range is 0 to 21. 0 disables the function.
Banner Alerts [51.63]
Use this option to program whether system alerts are displayed on the keypad banner. If
enabled, system events are indicated on the display. The default setting is disabled.
Set Override [51.64]
Use this option to change the type of user that can override specific fault events to set the
system.
A different value can be programmed for each group.
Reset levels [51.65]
This parameter determines the type of user that can reset specific fault types.
Note: This parameter affects and is affected by parameters 51.06 (System Reset), 51.07
(Tamper Reset) and 51.22 (PA Reset). If the parameter reset level is changed at
51.65 it is reflected at 51.06, 51.07 and 51.22.
Min PIN Size [51.66]
Use this option to set the minimum size of each user code. This can be set from four to six
digits. The default is four digits.
[51.67] Not used
Line Fail [51.68]
Use this option to program the period between the panel being alerted by a communication
module of a Line Fail condition and the user being alerted of the alarm condition.
The default is 50 seconds and the range is 0 to 1800 seconds.
86