Honeywell Galaxy Flex Installer Manual page 62

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Group Omit [46]
When you select the option the groups assigned to the user code and keypad are displayed as
well as the omit status of each group (Y below the group indicates that it is omitted, N
indicates that it is not omitted).
To omit a group, press the required key. The letter beneath the group number changes from
N to Y. To reinstate the group press the key to toggle from Y to N.
Notes:
1.
The type 6 user must have group choice to enter Group Omit.
2.
The zones in the selected groups are omitted from the system as soon as the group is
selected and ZONES OMITTED is displayed.
Omitted zones remain omitted for one set period only or until they are manually reinstated
to the system.
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as
the zone is omitted and remains active until the zone is reinstated. If the output mode is
programmed as latch, then the Zone Omit outputs activate when the system is set and remain
active until the system is unset, reinstating the omitted zones.
62
Galaxy Flex Installer Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents