Communications [56]
Fail to Comm [56.4.06]
Use this option to program the number of unsuccessful communication attempts before the
COMM FAIL message is recorded in the event log.
When an event is to be transmitted to the monitoring station, the Ethernet module attempts
to initiate a session with the destination receiver for each programmed transmission path. If
the programmed number of attempts is reached a Fail to Comm message is logged,
including which path has failed.
Note: If the receiver option is programmed as Dual then a successful transmission must be
made to both primary and secondary to be considered a successful transmission.
Line Fail [56.4.07]
The line fail option controls which Ethernet connections are monitored. The Ethernet
module can be programmed to monitor both the network availability and the programmed
transmission paths between the Ethernet module and receiver applications.
Line fail events (whether network or transmission path) must be present for the time
programmed in parameter 51.68 before the event is activated. If a line fail is present and an
attempt is made to set the system within parameter 51.68 delay period, the line fail will
immediately be logged and indicated.
Line Fail Network [56.4.07.1]
Use this option to monitor the connection between the Ethernet module and the local
network. 0=OFF and 1=Available. When set to 1=Available a Line Fail event is activated
if the Ethernet module is disconnected from the network or the local network is not available
at the panel.
Line Fail Signal Path [56.4.07.2]
Use this option to program which signalling paths are monitored by the Ethernet module.
The Ethernet module is programmed to expect a path supervision signal at the frequency
programmed in Alarm Reporting Heartbeat [56.4.02.7]. If the signal is not received a line
fail event is logged, which indicates the path that failed and the destination IP address of that
path.
Note: If groups are enabled a failure on the primary path will not provide specific IP
information.
Options are available to select specific paths or all paths.
1=Primary
Monitors the primary transmission path only.
2=Secondary
Monitors the secondary transmission path only.
3=Alarm Mon. Monitors the Alarm Mon. transmission path only.
4=Any
Monitors all transmission paths. If a supervision failure is detected in any
of the paths a line fail condition is activated.
5=All
Monitors all transmission paths. If a supervision failure is detected in all
of the paths a line fail condition is activated.