Diagnostics [61]
Timeline [61.2.2]
Use this option to show the time and date of the last check carried out for each of the areas
listed:
1=Batt Size
2=Batt RF
3=PSU Volts
4=RIO Volts
5=Zone Ohms
6=Communication
7=Panel Memory
9=Batt Volts
Record [61.2.3]
Use this option to start a baseline check of areas 1 to 7 in the table above. You are prompted
to press
to continue with the diagnostic check.
Checks [61.2.4]
Use this option to disable or enable each of the areas 1 to 9 listed above from the baseline
recording..
Print [61.2.5]
Use this option to print the stored baseline data via a print interface module on the RS485
line.
160
Battery size in Ah.
The battery status of all RF devices. Shows LOW if not OK.
The voltage level of all Smart PSUs in the system including onboard
PSUs.
The voltage level of all Smart PSUs in the system including the
onboard RIOs.
The current resistance across all zones in the system. For RF zones
signal strength and time since supervision are displayed.
Type of device, address, and the percentage level with all peripherals
in the system.
A check of the panel memory.
Voltage level of the battery connected to the control panel.
Galaxy Flex Installer Manual