numbers. After a successful communication the LED lights for three seconds, and the
module releases the telephone line and reconnects any serially connected equipment. This
procedure is repeated for the second telephone number if the Receiver option has been
programmed as Dual.
If the communication attempt is unsuccessful, the LED flashes rapidly for three seconds.
The communicator then waits for a short period before redialling the number (or the second
telephone number if the Receiver option has been programmed as Dual or Alternate).
When the Fail To Communicate option is set to the default value of 120 seconds a
communication Fail will be recognised if there has not been a successful kiss-off,
irrespective of the number of failed attempts. Bell Delay [51.2] is overridden when this
condition occurs.
The FAIL TO COMM parameter has 5 time values:
1=60 seconds; 2=120 seconds; 3=180 seconds; 4=240 seconds.
Note: If the Receiver option is set to Dual, then successful transmission must be made to
both telephone numbers.
Remote Access Period [56.1.12.1]
Use this option to control how the remote site is accessed by the Remote operator. There are
four modes:
1=Off
2=All Unset
3=Any Set
4=Any Time (default) Access available at any time.
Remote Access Mode [56.1.12.2]
1=Direct Access
2=Manager Authorize An authorized user can access the system via Remote Servicing in
Remote Servicing access to the panel is disabled.
Access only when all the groups are unset. If groups are not
enabled access is available at any time.
Remote Servicing access will only be granted if any of the groups
or the complete system are set.
Permits access at anytime. Once access is authorized, uploading,
downloading and remote servicing can begin.
these ways:
Timed Access: Remote Servicing must access the system
within 40 minutes of the option being enabled. Once
connected there is no time limit on the access period. After
terminating the connection, Remote Servicing can re-access
the system within 15 minutes of the termination.
Call Back: the manager instructs the panel to initiate a
connection to a computer (with Remote Servicing software
loaded) by dialling one of the numbers programmed in the
Call Back option.
Communications [56]
131