Program Zones [52]
23 Battery Low
This function is used to monitor the voltage output of a standby battery connected to a
power supply. The activation (+) and de-activation (–) of Battery Low zones is recorded in
the event log.
24 Line Fail
This function is used to monitor the communication line that a remote signalling device is
connected to for communications failure.
When the system is in the unset state, the first activation of a Line Fail zone causes a local
alarm and the message COMMS FAILURE is displayed, subsequent Line Fail activations
do not sound the local alarm; the only indication is the keypad display.
When the system is set, activation of the Line Fail zone overrides the Bell Delay parameter.
When the system is unset a local alarm is generated and the keypad gives an indication that
a Line Fail zone has activated. If an alarm condition occurs while the Line Fail is active, an
instant full alarm is generated.
If the Line Fail zone is active at the point of setting, a warning message is displayed. The
user can choose to continue or abort the setting procedure. It is also possible to prevent the
system setting if the Line Fail is active by enabling the Stop Set parameter (option 51.18).
25 AC Fail
This function is used to monitor a remote power supply. In the event of a power failure the
AC Fail zone is activated; the activation (+) and de-activation (–) of the zone is recorded in
the event log.
26 Log
This zone type has no operational function. It is designed to record the activation of a zone
in both the set and unset state. The activation (+) and de-activation (–) of Log zones is
recorded in the event log.
28 Video
This function is identical to the Intruder function, with the exception that the cumulative
number of activations from Video zones, before a full alarm is generated, is programmable.
The number of activations required is determined by the Video parameter (option 51.30).
The range is 1 to 9. The activation count is incremented when any Video zone in the group
activates. The count is reset to zero when the group is unset.
29 Video Exit
This function is identical to the Video function, with the exception that the user can activate
the zone during setting and unsetting without incrementing the Video activations count. The
Video output is not activated during setting and unsetting.
32 Set Log
This function is identical to the Log function, with the exception that zone activations are
only recorded in the event log during the set period.
100