Honeywell Galaxy Flex Installer Manual page 65

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual
INT Telecoms Call Back 1 to 5 [47.1.0.1 to 5]
ISDN Call Back 1 to 5 [47.1.1.1 to 5]
Ethernet Call Back 1 to 5 [47.1.2.1 to 5]
GSM Call Back 1 to 5 [47.1.3.1 to 5]
Use this option to pre-program up to five numbers (refer to Remote Access [56.1.12]).
When you select one of the numbers (1 to 5) and then press
pre-programmed telephone number associated with the Call Back number.
If the number selected does not have a pre-programmed telephone number, the system
prompts for a number to be entered. Enter the required telephone number and press
panel then dials out to the telephone number entered.
Note: The remote computer, to which the panel is dialling, must have remote servicing
software installed and the Communication Server must be running..
Auto Service [47.4]
You can program panels to communicate with remote servicing software automatically,
under three circumstances:
If site programming changes send the new programming to the downloader.
On a predetermined schedule, activate an automatic periodic upload.
On a predetermined schedule, activate an automatic remote routine inspection.
Note: The Auto Service function works for both the Internal Telecoms and the Ethernet
module.
Use the following sub-options to select the mode of the automatic communication in each of
the three situations.
Auto Service Mode Off [47.4.1.0]
In this mode the panel will not automatically initiate a remote servicing call even if the panel
programming has changed. This is the default setting.
Auto Service Mode Timed [47.4.1.1]
In this mode, following modification to panel programming, a remote servicing call is
initiated automatically between a programmed start time (option 47.4.2.1) and end time
(option 47.4.2.2). To avoid traffic congestion the panel selects a random time between the
start and end times to initiate the call. Once the connection is made, the new panel
programming is uploaded to the remote servicing package.
Auto Service Mode Instant [47.4.1.2]
In this mode, following modification to panel programming, the connection to the remote
servicing package is initiated immediately, using call back number 1, after you exit
engineering mode. Once the connection is made, the new programming is uploaded to the
remote servicing package.
Remote Access [47]
, the panel dials out to the
ent
. The
ent
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents