SIA Control [56.4.08]
When using the SIA control command protocol for integration purposes, enter the IP address
of the computer sending the SIA control commands to ensure that only commands from a
computer with the programmed IP address are recognised by the Ethernet module.
Enter the IP address in the form XXX.XXX.XXX.XXX. The dot separator is added
automatically after each sequence of three numbers. To add the separator manually press .
Encrypt [56.4.09]
The Ethernet module supports 128 bit encryption for all communication options. Use this
option to enable and disable encryption for each communication option. The default setting
is OFF for each option.
1=Alarm Report
2=Remote Access
3=SIA Control
4=Alarm Mon.
GPRS Network [56.4.10]
To enable GPRS operation you need to setup Format [56.4.02.1], Primary IP [56.4.02.2],
and Account No. [56.4.02.4] as well as the following options:
1=APN
The Access Point Name for the GPRS provider; a maximum of 30
characters.
2=Login
The login (username) for the GPRS provider; a maximum of 20 characters.
3=Password
The password for the GPRS provider; a maximum of 20 characters.
GSM [56.5]
The GSM module has the same menu structure and function as the Internal Telecoms
[56.1] with the following exception:
11=Fail to Comm
This is controlled by the number of attempts and not time.
Line Fail [56.5.10]
1=Network Fail (default Disabled) A line fail occurs if a network failure is detected. The
signal strength should be above 30% for reliability. Check this in the diagnostic menu
61.1.06.
SMS [56.5.17]
Use this option to generate and transmit SMS text messages in response to events that occur.
1=Mobile No.(s) Press ent to access and enter up to three mobile numbers (22 digits
Controls encryption for the Primary and Secondary alarm
transmission paths.
Controls encryption for the Remote Servicing sessions.
Controls encryption for communications between the Ethernet
module and remote computer using the SIA control command
protocol.
Controls encryption for the Alarm Monitoring alarm transmission
paths.