Communications [56]
If the communication attempt is unsuccessful, the communicator waits for a short period
before redialling the number (or the second telephone number if the Receiver option has
been programmed as Dual or Alternate). When the Fail To Communicate option is left at the
default setting of 3, and the first three dialling attempts are unsuccessful, the COMM FAIL
message is recorded in the event log and the alarms to be transmitted are erased from the
buffer.
Remote Access [56.3.09]
See Remote Access [56.1.12] for details.
Alarm Monitoring [56.3.10]
Use this option to allow events to be dialled to a computer with Alarm Monitoring software.
Alarm events information is only transmitted when all of the alarms have been sent to the
ARC (or all communication attempts have been unsuccessfully made). If a new alarm event
occurs while the system is transmitting in the Alarm Monitoring mode, the transmission is
terminated and the alarms are sent to the ARC using the primary format selected.
The menu structure and programming of the Alarm Monitoring options are identical to
Alarm Monitoring [56.1.14].