Galaxy Flex Installer Manual
RF Supervision [51.60.3]
1=Silent Alarm
2=Debounce
RF Bat Delay [51.60.4]
Use this option to give a warning at the panel if an RF low battery is detected. An additional
option allows a delay to be programmed of up to 100 hours (default) before a signal of RF
BAT LOW is sent to the ARC.
RF Jam Delay [51.60.5]
This option allows the RF Portal to send an RF jam signal to the panel if it detects
interference for 30 seconds. If the interference is continuously present for five minutes
(default), the signal is transmitted to the central station. The programmable range is 0 to 30
minutes.
RF Stop Set [51.60.6]
Enable this option to prevent setting if all supervised devices have not signalled to the
receiver in the stop set period, prior to setting. The range is 0 to 250 minutes. The default is
20 minutes.
RF Stop Mode [51.60.7]
This option controls whether, and how, an RF fault prevents the panel from being set. There
are three options:
0=Disabled
1=Warning
2=Auto Check
Activity Mon [51.61]
Use this option to check zone activity. If zones programmed for zone activity checks are not
activated within the programmed time period, and/or number of set/unset cycles, a zone
masked fault is indicated at the panel. Six different combinations of check criteria are
available for each zone.
Each criteria type can be programmed to check the number of days, the set/unset cycles or
both. The default value is both.
1=Mode
2=MAX Period
3=MAX Unsets
Stop supervision alarms from activating sounders when set.
Extends the normal 2 hour delay for supervision by a further 24 hours.
An RF fault will not prevent setting
If there is a failure the user will get a warning but can continue to set
If there is a failure the system cannot be set until the zone(s) have been
activated
The mode can be set to one of three options: Max Period, Max Unsets
or Either.
The time period that zone activity is checked can be set to between 1
and 28 days. The default is 14 days.
This is the number of programmable set/unset cycles that must take
place before a zone masked fault is indicated at the panel. The number
of set/unsets can be programmed from 1 to 10. The default is 7.
Parameters [51]
85