Telephone No. 2 [56.1.05]
A second telephone number is available to support Dual and Alternate dialling to a second
destination receiver. The programming is identical to Telephone Number 1 [56.1.02].
Dial Type [56.1.06]
Select a transmission mode:
1=Tone
also known as DTMF dial, is much quicker at dialling than the pulse option.
2=Pulse
also known as rotary or loop disconnect is universal, but an increasing number of
exchanges now provide the tone (DTMF dial) option.
Note: If unsure of the type of exchange that the panel is connected to, leave as Pulse
dialling.
Int Telecom Autotest [56.1.07]
Use this option to automatically transmit an engineer test to the Monitoring Station at
programmed intervals, to indicate alarm transmission path integrity.
1=Start Time
2=Intervals
3=Intelligent Test
Engineer Test [56.1.08]
Once an Account Number and Telephone Number 1 have been entered, you can use this
option to verify that the station is receiving transmissions sent from the module.
On selecting the option this warning message is displayed on the keypad:
WARNING!!!
ent=
Press
to send the engineer test.
ent
The test attempts to transmit once for each selection of the option. If the test is not
successfully transmitted, the communicator does not attempt to resend. An unsuccessful
transmission is not counted as a FAIL TO COMMUNICATE.
Note: Activation of an engineer test will send a test signal via all communication modules.
Enter the time the first engineer test is transmitted. Subsequent
engineer test transmissions are offset by the value assigned in the
Intervals option.
Sets the period between engineer test transmissions following the
Start Time. The range is 0 to 99 hours.
Notes:
1.
If the Test Interval is 0 (default) the Autotest is disabled, even
if a Start Time has been assigned.
2.
To disable Autotest enter 00:00 (default); no transmissions of
test signals can be sent at midnight.
Stops the transmission of an automatic engineer test if an alarm
signal has already been sent during the autotest interval.