Honeywell Galaxy Flex Installer Manual page 80

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Parameters [51]
1=PRINTER MODULE Switches the printer to online mode and requires a continuously
Note: If Online Print is enabled, the event log and other options will not be printed at the
user's request. The parameter must be disabled to permit all other print options to
operate.
Online Level [51.29]
Use this option to set the level of events that are printed when Online Print [51.28] is
enabled:
0 (default)
basic print (setting, unsetting, alarms).
1
full print excluding MAX events (setting, unsetting, alarms, modifications,
technical details).
2
full print including MAX events (all logged events).
3
MAX events only (only card events).
4
Basic Print plus MAX events (option 0 + MAX events).
Video [51.30]
Use this parameter to set the number of activations that must occur on any of the zones
programmed as Video, in a single set period, before a full alarm occurs. There is no time
limit on the period between activations. The Video parameter is programmable within the
range 1 to 9 activations, and the default value is 2. The video output occurs on every
activation but a full alarm does not occur until the programmed number of activations is
reached. The Video zones activation counter is reset when the system is unset.
Note: The activations of the Video zones are cumulative - the counter is incremented each
time any Video zone in the group is activated.
You can assign a different value to each group.
Show Alarms [51.32]
Use this parameter to display immediately, on all the keypads, the first alarm activation
when an alarm occurs. By default, alarm messages are not displayed until the alarm is
cancelled. Banner Alerts [51.63] must be enabled to view alarms on the keypad. The
default setting is disabled (0).
Note: This parameter only functions when at least one group is unset.
Secure Code [51.33]
Use this parameter to program the system to randomly change the engineer code each day at
08:00 hours. The service engineer must be given the code of the day by head office.
The random code is dependent on the local engineer code, therefore each area, company,
branch or even system can have a unique secure code.
80
connected printer. Events are printed as and when they occur.
The events printed are controlled by Online Level [51.29].
Galaxy Flex Installer Manual