5.3

Topology rules for Safety Integrated functions

Number
Port 1 at the PPU
of axes
X100
SINAMICS S120 booksize
5
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
6
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
7
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
8
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
8
1 x LM
4 x MoMo
1 x SMy at the 4th MoMo
SINAMICS S120 Combi
3
3x Combi
1xSMy at the Combi
4
3x Combi
1xSMy at the Combi
4
4x Combi
1xSMy at the Combi
5
4x Combi
1xSMy at the Combi
6
4x Combi
1xSMy at the Combi
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4
Port 2 at the PPU
X101
1 x TM54F
1x MoMo
1 x Hub DMx
4 x SMy at the Hub DMx
1 x TM54F
2x MoMo
1 x Hub DMx
5 x SMy at the Hub DMx
1 x TM54F
2x MoMo
1 x Hub DMx
5 x SMy at the Hub DMx
1 x TM54F
1x MoMo
1 x Hub DMx
4 x SMy at the Hub DMx
1 x TM54F
2x MoMo
1 x Hub DMx
5 x SMy at the Hub DMx
not used
1 x booksize compact
not used
1 x booksize compact
2 x booksize compact
Rules for permitted topologies
5.3 Topology rules for Safety Integrated functions
Port 3 at the PPU
X102
not used
not used
1 x NX10.3
1 x TM54F
1 x MoMo
1 x SMy at the MoMo
1 x NX10.3
1 x TM54F
3 x MoMo
1 x SMy at NX10.3
1 x SMy at TM54F
1 x SMy at the 3rd MoMo
1 x NX10.3
1 x TM54F
2 x MoMo
1 x SMy at NX10.3
1 x SMy at the 2nd MoMo
1 x TM54F
1 x Hub DMx
2 x SMy at the Hub DMx
1 x TM54F
1 x Hub DMx
3 x SMy at the Hub DMx
1 x TM54F
1 x Hub DMx
3 x SMy at the Hub DMx
1 x TM54F
1 x Hub DMx
4 x SMy at the Hub DMx
1 x TM54F
1 x Hub DMx
5 x SMy at the Hub DMx
Example in the figure:
---
---
---
Topology with SINAMICS
S120 Booksize 5+3 axes
(Page 63)
Topology with SINAMICS
S120 Booksize and 6+2
axes (Page 63)
---
---
---
---
---