Anschließbare Komponenten
7.5 MCP Interface PN
Name
Function
H501
BUS_SYNC
H502
BUS_FAULT
H505
Temperature alarm (red) Lit
7.5.1
Mounting
Installation
The module can be attached at a suitable position via the four mounting holes (e.g. behind the
machine control panel or in the control cabinet). The selection of the appropriate mounting
position depends on the interfaces used and the associated maximum cable lengths.
Four standard torx-slotted screws T20/M4 are used to attach the module.
MCP Interface PN dimension drawing
Figure 7-28
156
Status
Meaning
Not lit
No PROFINET communication.
Lit
PROFINET is synchronized (STOP state).
Flashes (0.5
PROFINET is synchronized (RUN state).
Hz)
Lit
PROFINET group fault.
At least one temperature limit is being exceeded.
MCP Interface PN dimension drawing
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4