Anschließbare Komponenten
7.10 NX10.3
Pin
13
14
An open input is interpreted as "low".
Note
Terminal M1 must be connected for the digital inputs (DI) 0 to 3 and 16/17 to function. This
can be done as follows:
● Connect the ground reference of the digital inputs.
● Jumper to terminal M: This removes the electrical isolation for these digital inputs.
Table 7-121 Technical data for X122
Parameter
Current consumption
Galvanic isolation
As an input
Voltage
Current consumption
Signal level (including ripple)
Signal propagation times
As an output
Voltage
Max. load current
252
Signal name
Meaning
DI/DO11
Digital input/output 11 (rapid input)
M
Ground
Value
Typical: 10 mA at 24 V DC
The reference potential is terminal M1
-3 V to 30 V
Typical: 10 mA at 24 V DC
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Inputs / "fast inputs":
L → H: approx. 50 μs/5 μs
H → L: approx. 100 μs/50 μs
24 V DC
Per output: 500 mA continuous short circuit-proof
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4