Technical Data - Siemens Sinumerik 828D Manual

Ppu and components
Hide thumbs Also See for Sinumerik 828D:
Table of Contents

Advertisement

Value
Cause
byte 1
5
Internal error, system error
6
Overrange at the inputs
7
Overrange at the outputs
The analog outputs retain their last specified value.
1)
Diagnostics via Status Bytes 0/1
In Status Byte 0, the set operating modes are reflected e.g. "0x55" if Control Byte 0 = 0x55
has been specified.
In the event of an error, the error bit is set in Status Byte 1 (bit 7). In the event of an error in
one channel, all channels are disabled.
Table 7-85
Input image of analog inputs (excerpt)
Byte
Bit7
m+0
0
m+1
Error bit
7.8.5

Technical data

PP 72/48D PN I/O module
Parameter
Input voltage
Power consumption at rated load
(without digital outputs)
Degree of protection in acc. with EN 60529
Protection class in acc. with EN 61800-5-1
Shock load during transport (in transport packag‐
ing)
Approvals
Cooling
Condensation
Relative humidity:
● Storage
● Transport
● Operation
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4
Effect
The "PNFault" LED is activated.
The outputs are disabled.
The value 0x80 is stored in Status Byte
1.
Bit6
Bit5
0
0
0
0
1)
Bit4
Bit3
0
0
0
0
Value
24 V DC + 20% / - 15%
17 W
IP00
III; DVC A (PELV)
Free-fall ≤ 1 m
CE, cULus
Open-circuit ventilation
Not permitted
5 ... 95 % no condensation
5 ... 95 % no condensation
5 ... 90 % no condensation
Anschließbare Komponenten
7.8 PP 72/48D PN
Remedy
The firmware has detected a system er‐
ror, this status can only be exited by
means of a switch-on / switch-off.
Check input circuit and adjust, if required.
Correct values in the user program.
Bit3
Bit1
0
0
0
0
Bit0
0
0
211