Anschließbare Komponenten
7.8 PP 72/48D PN
Note
A newly set PROFINET address will only come into effect after power OFF/ON.
The switch positions 9 and 10 guarantee the PROFINET functionality of the module and must
always be switched "ON".
Further information on the addressing can be found in Section Addressing components
(Page 256).
7.8.3.3

X111, X222 and X333 pin assignment

Pin assignment
Table 7-73
Pin
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
VI: Voltage input/VO: Voltage Output
I: Signal input/O: Signal output/GND: Reference potential (ground)
202
Pin assignment X111
Signal name
M
DI 0.0
DI 0.2
DI 0.4
DI 0.6
DI 1.0
DI 1.2
DI 1.4
DI 1.6
DI 2.0
DI 2.2
DI 2.4
DI 2.6
Not assigned
Not assigned
DO 0.0
DO 0.2
DO 0.4
DO 0.6
DO 1.0
DO 1.2
DO 1.4
DO 1.6
DOCOM1
DOCOM1
Type
Pin
Signal name
GND
2
P24OUT
I
4
DI 0.1
I
6
DI 0.3
I
8
DI 0.5
I
10
DI 0.7
I
12
DI 1.1
I
14
DI 1.3
I
16
DI 1.5
I
18
DI 1.7
I
20
DI 2.1
I
22
DI 2.3
I
24
DI 2.5
I
26
DI 2.7
-
28
Not assigned
-
30
Not assigned
O
32
DO 0.1
O
34
DO 0.3
O
36
DO 0.5
O
38
DO 0.7
O
40
DO 1.1
O
42
DO 1.3
O
44
DO 1.5
O
46
DO 1.7
VI
48
DOCOM1
VI
50
DOCOM1
Manual, 05/2015, 6FC5397-2DP40-3BA4
Type
VO
I
I
I
I
I
I
I
I
I
I
I
I
-
-
O
O
O
O
O
O
O
O
VI
VI