Parameter
Handwheel
Handwheel signals
Emergency Stop button
Enabling buttons
Axis selector switch
Degree of protection without shaft input ac‐
cording to EN 60529
Reliability, Emergency Stop button and ena‐
bling buttons
Relative humidity:
● Storage
● Transport
● Operation
Ambient temperature:
● Storage
● Transport
● Operation
Dimensions:
● Height
● Width
● Depth
Weight
Max. cable length
Approvals
Note
The quantitative assessment of the Emergency Stop and enabling safety functions must be
based on the B
consideration of the respective application (frequency of the actuation, service life, diagnostics
by the evaluation unit, etc.). The B
emergency stop and enabling buttons are taken into account.
Operator controls
Element
Acknowledgment button
Emergency Stop button
according to EN ISO 13850
Axis selector switch
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4
value corresponding to the used standards (e.g. ISO 13849-1) under
10d
value only applies when the technical properties of the
10d
Specification
Isolated, 2-channel
Isolated, 2-channel
5 axes:
X, Y, Z, 4. Axis, 5 Axis and neutral position
Anschließbare Komponenten
Value
100 pulses/rev
RS422
24 V DC, 2 A
24 V DC
24 V DC: 0.2 W
IP65
B
= 100 000
10d
Condensation not permissible
5 ... 95 %
5 ... 95 %
5 ... 95 %
-20 ... 60 °C
-20 ... 60 °C
0 ... 55 °C
180 mm
90 mm
67 mm
Approx. 0.5 kg without connecting cable
Approx. 1.3 kg with connecting cable
25 m
CE, cULus
7.7 Mini handheld unit
2 x NC contact
2 x NO contacts
Gray code
NO contact, 3-pole
NC contact, released by
twisting