Parameterization - Siemens Sinumerik 828D Manual

Ppu and components
Hide thumbs Also See for Sinumerik 828D:
Table of Contents

Advertisement

Table 7-29
Settings of switch S2
1
2
3
OFF
OFF
OFF
Further information on the addressing can be found in Section Addressing components
(Page 256).
7.4.4

Parameterization

The specifications for assigning input and output bytes listed in the tables are defined as
standard addresses in the PLC. Information on settings in the machine data can be found in
Section Activating components (Page 255).
Standard input image
Table 7-30
Input image MCP 310C PN
Byte
Bit7
EB112
* NC
stop
EB113
NC
start
EB114
Feed
start
EB115
RESET
EB116
+
EB117
T16
EB118
Freely assignable customer keys
T9
EB119
T1
EB120
-
EB121
-
EB122
KT-IN8
EB123
-
EB124
-
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4
4
5
6
ON
OFF
OFF
OFF
Bit6
Bit5
Spindle
Spindle -
100%
Spindle
* Spindle
right
stop
* Feed
INC VAR
stop
Keyswitch
Keyswitch
position 2
position 1
Direction keys
-
Rapid tra‐
verse
KT6
6
T10
T11
Freely assignable customer keys
T2
T3
-
-
-
-
KT-IN7
KT-IN6
-
-
-
-
7
8
9
10
ON
ON
OFF
Bit4
Bit3
Single
Spindle +
block
Spindle
Keyswitch
left
position 3
Keyswitch
INC 1000
position 0
E (2
)
D (2
)
4
3
KT5
KT4
5
4
T12
WCS
MCS
T4
T5
-
-
-
-
KT-IN5
KT-IN4
-
-
-
-
Anschließbare Komponenten
7.4 MCP 310C PN
Meaning
PROFINET address "64"
Bit2
Bit1
JOG
MDI
REF
REP
INC 100
INC 10
Feed override
C (2
)
B (2
)
2
1
KT3
KT2
Z
Y
Freely assignable customer keys
T13
T14
T6
T7
-
-
-
-
KT-IN3
KT-IN2
-
-
-
-
Bit0
AUTO
Teach
IN
INC 1
A (2
)
0
KT1
X
T15
T8
-
-
KT-IN1
KT-IN9
-
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents