Mounting - Siemens Sinumerik 828D Manual

Ppu and components
Hide thumbs Also See for Sinumerik 828D:
Table of Contents

Advertisement

Anschließbare Komponenten
7.3 MCP 483C PN
LEDs for status display
When the system is booting, all three LEDs are lit.
Name
Designation
H1
PowerOK
H2
PNSync
H3
PNFault
7.3.2

Mounting

Mounting sequence
The recommended installation of the MCP 483C PN machine control panel is shown in the
following figure:
Mounting positions
The permitted mounting position is max. 60° to the vertical.
Note
For mounting positions greater than 60°, a fan must also be installed to keep the ambient
temperature of the machine control panel constantly below 55° C.
Tension jacks
The machine control panel is mounted from the front in a rectangular cut-out and attached by
means of nine supplied tension jacks (0.5 Nm tightening torque).
124
Color
Description
Green
Lit: Power supply OK
Green
Lit: System software running, STOP state
Flashes 0.5 Hz: System software running, RUN state
Red
Not lit: Module is operating without errors; data exchange with all configured I/O devices
is running.
Lit: Serious bus fault; only output when one of the following errors is detected for the ports:
● No physical connection to a subnet/switch
● Incorrect transmission rate
● Full duplex transmission is not activated
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents