Single Regen, Single / Multiple Motoring System; Power Connections: Single Regen, Single / Multiple Motoring System - Emerson SP1201 Installation Manual

Unidrive sp regen series 200v 400v 575v 690v
Table of Contents

Advertisement

Safety
Product
Introduction
Information
information
4.2.1

Single Regen, single / multiple motoring system

Figure 4-1 Power connections: Single Regen, single / multiple motoring system
L1
L2
L3
F1
F2
F3
K1
VDR4
RFI
Charging branch circuit
Aux.2a
Aux.2b
K2
L1
OPD1
Table 4-1 Key to Figure 4-1
Key
L1, L2, L3
Three phase supply
F1, F2, F3
Main regen system supply fuses
VDR1, VDR2, VDR3 Varistor network line-to-line
VDR4, VDR5, VDR6 Varistor network line-to-ground
RFI
Optional RFI Filter
C1
Switching frequency filter capacitor
L1
Switching frequency filter inductor
L2
Regen inductor
K1
Main supply switch or contactor
K2
Regen drive main contactor
K3
Charging contactor
OPD1
Overload protection device for C1
Aux.3
K3 NC auxiliary contact
Aux.2a
K2 NO auxiliary contact
Aux.2b
K2 NC auxiliary contact
Aux.1
OPD1 NO auxiliary contact
Rly.1
Optional isolation for enable between Regen and motoring drive
Mt.1
Motor thermistor
Tc.1
Regen inductor thermistor
32
System
Mechanical
Electrical
design
installation
installation
VDR1
VDR3
VDR2
VDR6
Supply
ground
K3
Aux.3
L1
L2
L3
PE
AC Supply
Power-up
Connections
Regen drive
AC Supply
Connections
C1
U
V
W
Aux.1
L2
Description
www.controltechniques.com
Getting
Optimisation
Parameters
started
Vsupply
Aux.2b
Note: Surge suppressors to be fiited to contactor coils.
K3
Aux.3
Aux.2a
-DC +DC
21
22
23
24
25
Motoring
drive DC
Connections
1
2
3
4
5
6
7
8
Tc.1
Table 4-1 Key to Figure 4-1
Key
Vsupply
System control supply
+DC, -DC
Motoring drive power connection to Regen drive
S1
Regen drive enable
S2
Motoring drive enable
S3
Motoring drive reset
S4
Motoring drive run forward
S5
Motoring drive run reverse
S6
Regen drive reset input (Pr 8.24 = Pr 10.33)
Figure 4-1 shows both the power and control connections for the standard
regen solution this being a single regen and single motoring drive system.
For this solution the Vac supply is temporarily connected to the Regen
drive's L1, L2, L3 inputs for initial power-up only, removing the need for
an external charging circuit. The main AC supply to L1, L2, L3 on the
Regen drive (K3) is interlocked with the Regen drive's enable preventing
operation when the charging circuit is still connected.
NOTE
The regen inductor duty is very arduous and therefore selection is critical
as a result only Regen inductors specified in this guide should be used.
Technical
Component
data
sizing
-DC
+DC
S1
Aux.1
S6
Rly.1
(optional)
26
27
28
29
30
31
9
10
11
41
42
K2
Vsupply
Description
Unidrive SP Regen Installation Guide
Issue Number: 2
Diagnostics
T.24
T.30

Hide quick links:

Advertisement

Table of Contents
loading